Catalog No:

NRPB112L

Product Name:

NuPerley IMAC


NuPerley IMAC and NuPerley Ni-NTA are metal chelating fillers containing nitrilotriacetic acid (NTA) groups, which are mainly used for Affinity chromatograph of histidine-tagged (His-tag) proteins, and are NuPerley as a new generation of high rigidity agarose gel base microspheres developed for NUPTEC biology. NuPerley IMAC does not chelate metal ions, users can chelate Ni2, Co2, Cu2, Zn2 and other metal ions after use, NuPerley Ni-NTA has chelated Ni2, users can directly use.

Product features and technical indicators

Product Name

NuPerley IMAC

NuPerley Ni-NTA

Catalog No.

NRPB112L, NRPB112S (pre-installed column)

NRPB134L, NRPB134S (pre-installed column)

matrix

high rigidity agarose

ligand

Nitrilotriacetic acid, chelating ~ 23 μmol Ni2 /ml

Nitrilotriacetic acid, pre-chelated ~ 23 μmol Ni2 /ml

Particle size rangea

30 to 100 μm

average particle size

~ 60 μm

Dynamic binding loadb

~ 50 mg/mL Histidine-tagged protein

recommend working flow rate

60~300 cm/h

Maximum flow rate and pressurec

1500 cm/h,0.5 MPa

pH stability

3~12 (recommend working pH),3~12 (long-term stability);2~14 (short-term stability) d

chemical stability

It is stable in the following solutions: commonly used aqueous buffer, 1 mol/L sodium hydroxide, 8 mol/L urea, 6 mol/L guanidine hydrochloride, 70% ethanol, etc. The effects of common reducing agents, chelating agents, detergents, denaturants, etc. on fillers are shown in the table below.

Storage and transportation

20% ethanol, 2~30 ℃

Shelf life

5 years